TimePix3 measurements in SOBP and IMPT fields
Loading...

Date
2025-04-15
Authors
Stasica, Paulina
Granja Carlos
Kopeć, Renata
Krzempek, Dawid
Oancea, Cristina
Ruciński Antoni
Rydygier Marzena
Winiarz Mateusz
Gajewski Jan
Journal Title
Journal ISSN
Volume Title
Publisher
Institute of Nuclear Physics Polish Academy of Sciences
Abstract
The experimental data supporting results presented in Stasica-Dudek, et al. 2025 Phys. Med. Biol. (https://doi.org/10.1088/1361-6560/adcaf9). The measurements were performed with a Timepix3 MiniPIX detector with a 300 um silicon sensor operated in data-driven mode. Folders „sobp”, „impt-a”, „impt-b” and „impt-c”, refer to measurements performed for a given setup and irradiation plan presented in the manuscript. Each of these folders contains multiple subfolders corresponding to individual measurements performed separately for each energy layer of the irradiation plans. The subfolder names are the values of the scanning beam energy. Each subfolder contains .T3PA (Tpx3 pixels ASCII) text files consisting of tab-separated columns. Each row contains information on the pixel index in the matrix, Time of Arrival (ToA), fast Time of Arrival (fToA), and Time over Threshold (ToT). The folder „calibration matrices” contains text files with the matrices of calibration coefficients a, b, c, and t for each pixel needed for per-pixel deposited energy computation.
Description
Keywords
Citation
Sponsorship:
The work was supported by the National Center for Research and Development (NCBiR) within grant No. LIDER/43/0222/L-12/20/NCBR/2021.
Grantnumber:
LIDER/43/0222/L-12/20/NCBR/2021
License Type