Repository logo
 

Przystosowywanie cyklotronu AIC-144 do protonowej radioterapii oka część 5. Stabilność wiązki protonów w cyklotronie AIC-144: wybrane parametry, przyczyny i przeciwdziałania niestabilności

dc.contributor.authorDaniel, Krzysztof
dc.contributor.authorCieślik, Robert
dc.contributor.authorGuguła, Konrad
dc.contributor.authorGrzybek, Krzysztof
dc.contributor.authorGrzybek, Ryszard
dc.contributor.authorJanik, Grzegorz
dc.contributor.authorLipka, Bogdan
dc.contributor.authorMolęda, Janusz
dc.contributor.authorNorys, Tadeusz
dc.contributor.authorPyzioł, Wojciech
dc.contributor.authorRuszel, Marek
dc.contributor.authorSałach, Bogusław
dc.contributor.authorSulikowski, Jacek
dc.contributor.authorSroka, Artur
dc.contributor.authorTarczoń, Ryszard
dc.contributor.authorWłodek, Lucyna
dc.date.accessioned2018-01-11T14:13:05Z
dc.date.available2018-01-11T14:13:05Z
dc.date.issued2009
dc.description.abstractThe cyclotron AIC – 144 at IFJ PAN in Krakow has been intended to the proton therapy of the eye tumor. The non-standard requirements of the protons beam parameters for therapy, forced screw of the machine to do adaptation and improvement of the cyclotron systems. The last few years was dedicated to exchange the old systems to the new like: vacuum system, main magnet power supply, RF system, beam line system, beam line powers supplies. That work allowed doing the tests on the proton beam in treatment room. During tests the problems of protons beam stability of current and repeatability of protons beam of parameters has bean notice. Two themes have been presented in following article: the stability of the protons beam current in short time period; the repeatability of the protons beam parameters in long time period. Several factors can affect stability of current of protons beam. The most important are: work of ion source, long time of thermal stabilization of cyclotrons elements, variable of network of power supply. The main reason of repeatability of the protons beam parameters is capability of relocation acceleration chamber with respect to main magnet yoke.pl_PL.UTF-8
dc.identifier.urihttp://rifj.ifj.edu.pl/handle/item/134
dc.language.isopolpl_PL.UTF-8
dc.publisherInstitute of Nuclear Physics Polish Academy of Sciencespl_PL.UTF-8
dc.relation.ispartofseriesRaport IFJ PAN;2032/AP
dc.titlePrzystosowywanie cyklotronu AIC-144 do protonowej radioterapii oka część 5. Stabilność wiązki protonów w cyklotronie AIC-144: wybrane parametry, przyczyny i przeciwdziałania niestabilnościpl_PL.UTF-8
dc.typeReportpl_PL.UTF-8

Files

Original bundle
Loading...
Thumbnail Image
Name:
2032.pdf
Size:
753.59 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Loading...
Thumbnail Image
Name:
license.txt
Size:
846 B
Format:
Item-specific license agreed upon to submission
Description: