Repozytorium IFJ PAN

Przeglądaj według autora "Daniel, Krzysztof"

Przeglądaj według autora "Daniel, Krzysztof"

Sortuj według: Kolejność: Wyniki:

  • Guguła, Konrad; Daniel, Krzysztof; Duszyc, Michał; Janik, Grzegorz; Koczot, Andrzej; Michalec, Barbara; Pasiecznik, Tomasz; Raczyński, Łukasz; Suder, Krzysztof; Winiarz, Mateusz; Kopeć, Renata (Institute of Nuclear Physics Polish Academy of Sciences, 2017)
    The purpose of the report is to introduce work necessary to determine impact of selected cyclotron Proteus C-230 parameters affecting workflow of Proteus 235 Proton Therapy System, which is located inside ...
  • Bogdali, Paweł; Sulikowski, Jacek; Sroka, Artur; Rogóż-Duda, Agnieszka; Cieślik, Robert; Daniel, Krzysztof; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Molęda, Janusz; Nowak, Tomasz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sumera, Maciej (Institute of Nuclear Physics Polish Academy of Sciences, 2017)
    In 2016, eye therapy was transferred to the new Proteus-235 cyclotron. The work of Cyclotron AIC-144 has become research and development. Reducing the demand for a proton beam has contributed to significant ...
  • Sroka, Artur; Rogóż-Duda, Agnieszka; Sumera, Maciej; Bogdali, Paweł; Cieślik, Robert; Grzybek, Ryszard; Lipka, Bogdan; Michałowski, Henryk; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Daniel, Krzysztof; Kochański, Wojciech; Wojas, Damian (Institute of Nuclear Physics Polish Academy of Sciences, 2015)
    Cyclotron AIC-144 forming part of the Cyclotron Center Bronowice was built as a universal device research and development, which enabled the acceleration of three types of particles: alpha, deuterons and protons with ...
  • Cieślik, Robert; Daniel, Krzysztof; Grzybek, Ryszard; Guguła, Konrad; Janik, Grzegorz; Koczot, Andrzej; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Amirkhanov, I.; Karamysheva, G.; Kiyan, I.; Morozov, N.; Samsonov, E. (Institute of Nuclear Physics Polish Academy of Sciences, 2012)
    The latest computational and experimental results concerning 60 MeV proton beam acceleration and extraction in AIC-144 cyclotron of the Institute of Nuclear Physics (Krakow, Poland) are being considered. Improvement of RF ...
  • Bakewicz, Edmund; Daniel, Krzysztof; Doruch, Henryk; Petelenz, Barbara; Tałach, Marek; Szałkowski, Mirosław (Institute of Nuclear Physics Polish Academy of Sciences, 2003)
    Cyklotron AIC-144 Instytutu Fizyki Jądrowej PAN w Krakowie, modernizowany w celu jego przyszłych zastosowań medycznych, jest od roku 2000 coraz intensywniej wykorzystywany do otrzymywania izotopów. Odpowiednie tarcze są ...
  • Suder, Krzysztof; Daniel, Krzysztof; Guguła, Konrad; Janik, Grzegorz; Kamiński, Łukasz; Koczot, Andrzej; Jabłońska, Magdalena; Raczyński, Łukasz; Ruszel, Marek; Winiarz, Mateusz (Institute of Nuclear Physics Polish Academy of Sciences, 2014)
    The goal of this report is to present to possibility of modernization of AIC-144 cyclotron's safety systems. The actual status is described and possible solution offered. The core of the new safety system is Siemens Simatic ...
  • Kamiński, Łukasz; Daniel, Krzysztof; Duszyc, Michał; Guguła, Konrad; Janik, Grzegorz; Koczot, Andrzej; Jabłońska, Magdalena; Pasiecznik, Tomasz; Raczyński, Łukasz; Suder, Krzysztof; Winiarz, Mateusz; Rogóż-Duda, Agnieszka; Kopeć, Renata (Institute of Nuclear Physics Polish Academy of Sciences, 2016)
    The project involved creation of the control system for the beam production system in order to allow measurements of the proton energy using TOF method. Two conceptual solutions were considered. Triggering system based on ...
  • Daniel, Krzysztof; Guguła, Konrad; Grzybek, Ryszard; Janik, Grzegorz; Kisielowski, Andrzej; Bochenek-Dobrowolski, Ryszard; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2007)
    This article was devote to the adaptation of cyclotron AIC 144 to the radiotherapy of eye melanoma. First part described the optimization of energy and shapes the protons beam, which was made by the specialist from Joint ...
  • Daniel, Krzysztof; Doruch, Henryk; Lipka, Bogdan; Norys, Tadeusz; Sulikowski, Jacek; Sroka, Artur (Institute of Nuclear Physics Polish Academy of Sciences, 2005)
    The AIC-144 cyclotron at the Institute of Nuclear Physics has been upgraded to produce the beams, which could be applied for proton radiotherapy of eye melanoma. Acceleration, extraction and transport of the 56 MeV proton ...
  • Daniel, Krzysztof; Cieślik, Robert; Guguła, Konrad; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2008)
    This article concerns adaptation of the cyclotron AIC-144 to radiotherapy of eye melanoma. The first part of the article describes suppression of residual fumes inside the cyclotron chamber. In order to attain this new ...
  • Daniel, Krzysztof; Cieślik, Robert; Guguła, Konrad; Grzybek, Krzysztof; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2009)
    The cyclotron AIC – 144 at IFJ PAN in Krakow has been intended to the proton therapy of the eye tumor. The non-standard requirements of the protons beam parameters for therapy, forced screw of the machine to do adaptation ...
  • Daniel, Krzysztof; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2010)
    The cyclotron AIC – 144 at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN) in Krakow has been dedicated to the proton therapy of the protons eye tumor. In this application, the essential parameter is ...
  • Daniel, Krzysztof; Bochenek-Dobrowolski, Ryszard; Doruch, Henryk; Guguła, Konrad; Grzybek, Ryszard; Janik, Grzegorz; Kisielowski, Andrzej; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2006)
    The AIC-144 cyclotron at the Institute of Nuclear has been upgraded to produce the beams, which could be applied for proton radiotherapy of eye melanoma. For the improvement of quality of ion beam is necessary to better ...
  • Daniel, Krzysztof; Cieślik, Robert; Grzybek, Ryszard; Guguła, Konrad; Janik, Grzegorz; Koczot, Andrzej; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sroka, Artur; Sulikowski, Jacek; Tarczoń, Ryszard (Institute of Nuclear Physics Polish Academy of Sciences, 2011)
    The cyclotron AIC-144, currently used in proton radiotherapy of eye melanoma, is located in the Institute of Nuclear Physics in Cracow. The efficiency of protons deflection of this cyclotron, after elements of pole tip ...
  • Daniel, Krzysztof; Tałach, Marek (Institute of Nuclear Physics Polish Academy of Sciences, 2005)
    Praca przedstawia metodę obliczania pól magnetycznych w komorze akceleracji cyklotronu na podstawie wyników niepełnych pomiarów magnetycznych. Dużą uwagę położono na dokładność obliczeń, a w szczególności na uwzględnienie ...
  • Daniel, Krzysztof; Janik, Grzegorz; Norys, Tadeusz (Institute of Nuclear Physics Polish Academy of Sciences, 2010)
    W ramach przygotowania cyklotronu AIC-144 do uruchomienia protonowej terapii oka zmodernizowano układ transportu wiązki protonów na stanowisko terapii. Przedmiotem opracowania jest system sterowania zasilaczami podłączonymi ...