Repozytorium IFJ PAN

Browsing Publikacje by Author "Ruszel, Marek"

Browsing Publikacje by Author "Ruszel, Marek"

Sort by: Order: Results:

  • Bogdali, Paweł; Sulikowski, Jacek; Sroka, Artur; Rogóż-Duda, Agnieszka; Cieślik, Robert; Daniel, Krzysztof; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Molęda, Janusz; Nowak, Tomasz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sumera, Maciej (Institute of Nuclear Physics Polish Academy of Sciences, 2017)
    In 2016, eye therapy was transferred to the new Proteus-235 cyclotron. The work of Cyclotron AIC-144 has become research and development. Reducing the demand for a proton beam has contributed to significant ...
  • Sroka, Artur; Bogdali, Paweł; Cieślik, Robert; Grzybek, Ryszard; Lipka, Bogdan; Michałowski, Henryk; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Rogóż, Agnieszka; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sumera, Maciej (Institute of Nuclear Physics Polish Academy of Sciences, 2013)
    Cyclotron AIC-144, currently used in proton radiotherapy of eye melanoma, is located in Cracow at the Institute of Nuclear Physics Polish Academy of Sciences. The presented report describes the current state of the Cyclotron ...
  • Rogóż-Duda, Agnieszka; Sumera, Maciej; Bogdali, Paweł; Cieślik, Robert; Grzybek, Ryszard; Koczot, Andrzej; Lipka, Bogdan; Michałowski, Henryk; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sroka, Artur; Sulikowski, Jacek (Institute of Nuclear Physics Polish Academy of Sciences, 2014)
    Cyclotron AIC-144 is located in Krakow at the Institute of Nuclear Physics. It is currently used in proton radiotherapy ocular melanoma. This report presents the current state of the cyclotron and presents the work that ...
  • Sroka, Artur; Rogóż-Duda, Agnieszka; Sumera, Maciej; Bogdali, Paweł; Cieślik, Robert; Grzybek, Ryszard; Lipka, Bogdan; Michałowski, Henryk; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Daniel, Krzysztof; Kochański, Wojciech; Wojas, Damian (Institute of Nuclear Physics Polish Academy of Sciences, 2015)
    Cyclotron AIC-144 forming part of the Cyclotron Center Bronowice was built as a universal device research and development, which enabled the acceleration of three types of particles: alpha, deuterons and protons with ...
  • Cieślik, Robert; Daniel, Krzysztof; Grzybek, Ryszard; Guguła, Konrad; Janik, Grzegorz; Koczot, Andrzej; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Amirkhanov, I.; Karamysheva, G.; Kiyan, I.; Morozov, N.; Samsonov, E. (Institute of Nuclear Physics Polish Academy of Sciences, 2012)
    The latest computational and experimental results concerning 60 MeV proton beam acceleration and extraction in AIC-144 cyclotron of the Institute of Nuclear Physics (Krakow, Poland) are being considered. Improvement of RF ...
  • Suder, Krzysztof; Daniel, Krzysztof; Guguła, Konrad; Janik, Grzegorz; Kamiński, Łukasz; Koczot, Andrzej; Jabłońska, Magdalena; Raczyński, Łukasz; Ruszel, Marek; Winiarz, Mateusz (Institute of Nuclear Physics Polish Academy of Sciences, 2014)
    The goal of this report is to present to possibility of modernization of AIC-144 cyclotron's safety systems. The actual status is described and possible solution offered. The core of the new safety system is Siemens Simatic ...
  • Daniel, Krzysztof; Guguła, Konrad; Grzybek, Ryszard; Janik, Grzegorz; Kisielowski, Andrzej; Bochenek-Dobrowolski, Ryszard; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2007)
    This article was devote to the adaptation of cyclotron AIC 144 to the radiotherapy of eye melanoma. First part described the optimization of energy and shapes the protons beam, which was made by the specialist from Joint ...
  • Daniel, Krzysztof; Cieślik, Robert; Guguła, Konrad; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2008)
    This article concerns adaptation of the cyclotron AIC-144 to radiotherapy of eye melanoma. The first part of the article describes suppression of residual fumes inside the cyclotron chamber. In order to attain this new ...
  • Daniel, Krzysztof; Cieślik, Robert; Guguła, Konrad; Grzybek, Krzysztof; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2009)
    The cyclotron AIC – 144 at IFJ PAN in Krakow has been intended to the proton therapy of the eye tumor. The non-standard requirements of the protons beam parameters for therapy, forced screw of the machine to do adaptation ...
  • Daniel, Krzysztof; Grzybek, Ryszard; Janik, Grzegorz; Lipka, Bogdan; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sulikowski, Jacek; Sroka, Artur; Tarczoń, Ryszard; Włodek, Lucyna (Institute of Nuclear Physics Polish Academy of Sciences, 2010)
    The cyclotron AIC – 144 at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN) in Krakow has been dedicated to the proton therapy of the protons eye tumor. In this application, the essential parameter is ...
  • Nowak, Tomasz; Sulikowski, Jacek; Bogdali, Paweł; Cieślik, Robert; Grzybek, Ryszard; Lipka, Bogdan; Molęda, Janusz; Ruszel, Marek; Sałach, Bogusław; Sroka, Artur; Sumera, Maciej; Pyzioł, Wojciech; Zbroja, Katarzyna; Rogóż-Duda, Agnieszka; Mojżeszek, Natalia; Ogrodowicz, Ewa; Durlak, Edyta; Mierzwińska, Gabriela; Rydygier, Marzena (Institute of Nuclear Physics Polish Academy of Sciences, 2016)
    W hali eksperymentalnej budynku cyklotronu AIC-144, na jednym z wyjść magnesu M2, ustawiono tymczasowe stanowisko do pomiarów parametrów wiązki protonowej. Kierunek prowadzenia wiązki ustawiono precyzyjnie wykorzystując ...
  • Daniel, Krzysztof; Cieślik, Robert; Grzybek, Ryszard; Guguła, Konrad; Janik, Grzegorz; Koczot, Andrzej; Molęda, Janusz; Norys, Tadeusz; Pyzioł, Wojciech; Ruszel, Marek; Sałach, Bogusław; Sroka, Artur; Sulikowski, Jacek; Tarczoń, Ryszard (Institute of Nuclear Physics Polish Academy of Sciences, 2011)
    The cyclotron AIC-144, currently used in proton radiotherapy of eye melanoma, is located in the Institute of Nuclear Physics in Cracow. The efficiency of protons deflection of this cyclotron, after elements of pole tip ...
  • Ochab, Ewa; Petelenz, Barbara; Szałkowski, Mirosław; Ruszel, Marek; Sroka, Artur; Bogdali, Paweł (Institute of Nuclear Physics Polish Academy of Sciences, 2014)
    Two gallium isotopes, 66Ga (T1/2=9.4h, β+ 4.2MeV) and 67Ga (T1/2=78h, EC), can serve as good models in development of new 68Ga-labelled (T1/2=68m, β+ 1.9MeV) PET radiopharmaceuticals. In order to produce 66Ga and/or 67Ga ...