Repozytorium IFJRepozytorium cyfrowe IFJ PAN zapisuje, przechowuje, indeksuje i udostępnia cyfrowe materiały.https://rifj.ifj.edu.pl:4432024-03-18T17:56:57Z2024-03-18T17:56:57ZOptically stimulated luminescent response of the LiMgPO4 silicone foils to protons and its dependence on proton energySądel, MichałGrzanka, LeszekSwakoń, JanBaran, JakubGajewski, JanBilski, Pawełhttp://rifj.ifj.edu.pl/handle/item/4232024-03-12T12:24:51Z2023-01-01T00:00:00ZOptically stimulated luminescent response of the LiMgPO4 silicone foils to protons and its dependence on proton energy
Sądel, Michał; Grzanka, Leszek; Swakoń, Jan; Baran, Jakub; Gajewski, Jan; Bilski, Paweł
The prototype of the LiMgPO4 (LMP) silicone foils has been tested to find their OSL relative response to protons and their dependence on proton energy. The proton depth–-dose distribution was measured for the pristine monoenergetic 58 MeV Bragg Peak (BP) available from the AIC-144 isochronous cyclotron. 40 LMP flat sheet silicone foils stacked together inside a specially designed PMMA phantom, have been irradiated in the therapeutic room of the proton eye radiotherapy facility (IFJ PAN). The Co-60 gamma source in the same facility was used as the reference radiation. The data provided raw images registered for each LMP silicone foil after irradiation with protons and images captured after irradiation with the reference Co-60 gamma source and metadata. Data were used in the paper: Sądel Michał, Leszek Grzanka, Jan Swakoń, Jakub Baran, Jan Gajewski, and Paweł Bilski. 2023. "Optically Stimulated Luminescent Response of the LiMgPO4 Silicone Foils to Protons and Its Dependence on Proton Energy" Materials 16, no. 5: 1978. https://doi.org/10.3390/ma16051978; Prototypowe folie silikonowe na bazie LiMgPO4 (LMP) przetestowano, w celu wyznaczenia ich względnej wydajność luminescencyjnej (OSL) na protony oraz ich zależność od energii protonów. Zmierzono rozkład głębokościowy dawki protonów dla monoenergetycznej wiązki tzw. pojedynczy Pik Bragga (BP), dostępnej z izochronicznego cyklotronu AIC-144, w pomieszczeniu terapeutycznym radioterapii protonowej oka (IFJ PAN). Napromienianiu poddano 40 płaskich folii silikonowych, ułożonych wewnątrz specjalnie zaprojektowanego fantomu PMMA w formie stosu. Jako promieniowanie referencyjne wykorzystano źródło gamma Co-60. Udostępnione dane składają się z zestawu surowych obrazów zarejestrowanych dla każdej z 40 folii LMP, napromienionej wiązką protonów oraz promieniowaniem gamma, przy użyciu dedykowanego systemu obrazowania optycznego, składającego się ze źródła LED oraz wysokoczułej kamery CCD wraz z metadanymi. Udostępnione dane wykorzystane zostały w artykule: Sądel Michał, Leszek Grzanka, Jan Swakoń, Jakub Baran, Jan Gajewski, and Paweł Bilski. 2023. "Optically Stimulated Luminescent Response of the LiMgPO4 Silicone Foils to Protons and Its Dependence on Proton Energy" Materials 16, no. 5: 1978. https://doi.org/10.3390/ma16051978
2023-01-01T00:00:00ZPomiar rozpadów rozciągniętych stanów rezonansowych w jądrze 14NCieplicka-Oryńczak, N.Fornal, B.Leoni, S.Ciemała, M.Ziliani, S.Kmiecik, M.Maj, A.Łukasik, J.Pawłowski, P.Sowicki, B.Wasilewska, B.Ziębliński, M.Bednarczyk, P.Boiano, C.Bottoni, S.Bracco, A.Brambilla, S.Ciepał, I.Clisu, C.Crespi, F.C.L.Dhanmeher, K.Florea, N.Gamba, E.Grębosz, J.Harakeh, M.N.Iskra, Ł.Krzysiek, M.Kulessa, P.Marginean, R.Matea, I.Matejska-Minda, M.Mazurek, K.Parol, W.Sferrazza, M.Stan, L.Włoch, B.http://rifj.ifj.edu.pl/handle/item/4222024-03-12T09:31:56Z2024-01-01T00:00:00ZPomiar rozpadów rozciągniętych stanów rezonansowych w jądrze 14N
Cieplicka-Oryńczak, N.; Fornal, B.; Leoni, S.; Ciemała, M.; Ziliani, S.; Kmiecik, M.; Maj, A.; Łukasik, J.; Pawłowski, P.; Sowicki, B.; Wasilewska, B.; Ziębliński, M.; Bednarczyk, P.; Boiano, C.; Bottoni, S.; Bracco, A.; Brambilla, S.; Ciepał, I.; Clisu, C.; Crespi, F.C.L.; Dhanmeher, K.; Florea, N.; Gamba, E.; Grębosz, J.; Harakeh, M.N.; Iskra, Ł.; Krzysiek, M.; Kulessa, P.; Marginean, R.; Matea, I.; Matejska-Minda, M.; Mazurek, K.; Parol, W.; Sferrazza, M.; Stan, L.; Włoch, B.
Zbiór danych koincydencyjnych w postaci macierzy Egamma-Ex (energia kwantów gamma, wyrażona w keV, vs. energia wzbudzenia jądra 14N, wyrażona w MeV) zgromadzonych podczas eksperymentu rozpraszania nieelastycznego wiązki protonów na tarczy 14N („Study of M4 stretched configurations decay in 14N”) przeprowadzonego w CCB IFJ PAN. Zapis danych zgodny z formatem ROOT.; The set of coincidence data in a form of the Egamma-Ex matrix (gamma energy, in keV, vs. excitation energy of the 13C nucleus, in MeV) collected during the experiment with inelastic scattering of proton beam on the 14N target („Study of M4 stretched configuration decay in 14N”) performed at CCB IFJ PAN. The data are saved in ROOT format.
Dane zebrane w wyniku realizacji projektu SONATA NCN pt. "Fizyka otwartych układów kwantowych jądra atomowego badana w rozpadach rezonansów przyprogowych oraz "rozciągniętych" w lekkich jądrach"
2024-01-01T00:00:00ZDetection of proton tracks with LiF fluorescent nuclear track detectorsBilski, PawełSankowska, MałgorzataMarczewska, BarbaraKilian, AnnaSwakoń, JanSiketic, ZdravkoOlko, Pawełhttp://rifj.ifj.edu.pl/handle/item/4212024-03-11T11:57:31Z2024-03-11T00:00:00ZDetection of proton tracks with LiF fluorescent nuclear track detectors
Bilski, Paweł; Sankowska, Małgorzata; Marczewska, Barbara; Kilian, Anna; Swakoń, Jan; Siketic, Zdravko; Olko, Paweł
Fluorescent nuclear track detectors based on LiF crystals were successfully applied for detection of proton induced tracks. Irradiations were performed with protons with energy ranging from 1 MeV up to about 56 MeV and for all proton energies the fluorescent tracks were observed. The tracks are not continuous, but consist of a series of bright spots. The gaps between spots tend to narrow with decreasing proton energy (increasing ionization density). For the highest of the studied energies, the spots are scattered so sparsely, that it is not possible to link spots belonging to one track. The intensity (brightness) of the fluorescent tracks increases with the increasing LET and agrees well with the trend established earlier for various heavier ions. The data provided are: 1) Set of raw images registered for LiF crystals after irradiation with protons with energy ranging from 6.4 MeV to 56.3 MeV, together with metadata. 2) Numerical data on the relationship between the LET of protons and the recorded track intensity, as well as the number of recorded tracks (fraction of detected protons). Data were used in the paper: Bilski, P., Marczewska, B., Sankowska, M., Kilian, A., Swakoń, J., Siketić, Z., Olko, P., Detection of proton tracks with LiF fluorescent nuclear track detectors, Radiation Measurements (2024), doi: https://doi.org/10.1016/j.radmeas.2024.107083. This work was funded by the National Science Centre, Poland (grant No 2020/39/B/ST9/00459).; Fluorescencyjne detektory śladów cząstek jądrowych z kryształów LiF zostały z powodzeniem zastosowane do detekcji śladów wywołanych przez protony. Napromieniania zostały zrealizowane z wykorzystaniem protonów o energiach od 1 MeV do 56 MeV i dla wszystkich energii możliwe było zaobserwowanie fluorescencyjnych śladów. Ślady nie są ciągłe, ale składają się z ciągów jasnych punktów. Przerwy pomiędzy punktami mają tendencję do zmniejszania się wraz z malejącą energią protonów (zwiększającą się gęstością jonizacji). Dla najwyższych badanych energii, jasne punkty są rozproszone tak bardzo, że niemożliwym jest połączenie punktów należących do jednego śladu. Intensywność (jasność) śladów fluorescencyjnych wzrasta wraz ze wzrastającym współczynnikiem LET i zgadza się z trendem wyznaczonym wcześniej dla różnych cięższych jonów. Udostępnione dane to: 1) Zbiór surowych obrazów zarejestrowanych dla kryształów LiF po napromienieniu protonami o energiach od 6.4 MeV do 56.3 MeV, wraz z metadanymi. 2) Dane liczbowe dotyczące zależność między współczynnikiem LET protonów a intensywnością rejestrowanych śladów oraz liczbą rejestrowanych śladów (odsetek rejestrowanych protonów). Udostępnione dane wykorzystane zostały w artykule: Bilski, P., Marczewska, B., Sankowska, M., Kilian, A., Swakoń, J., Siketić, Z., Olko, P., Detection of proton tracks with LiF fluorescent nuclear track detectors, Radiation Measurements (2024), doi: https://doi.org/10.1016/j.radmeas.2024.107083. Badania finansowane były przez Narodowe Centrum Nauki (projekt numer 2020/39/B/ST9/00459).
2024-03-11T00:00:00ZDane uzyskane w wyniku realizacji projektu „Nowe bioaktywne powłoki kompozytowe na bazie nanostruktur krzemionkowych dla zastosowań biologicznych i środowiskowych”Laskowska, Magdalenahttp://rifj.ifj.edu.pl/handle/item/4192024-03-04T11:41:46Z2024-01-01T00:00:00ZDane uzyskane w wyniku realizacji projektu „Nowe bioaktywne powłoki kompozytowe na bazie nanostruktur krzemionkowych dla zastosowań biologicznych i środowiskowych”
Laskowska, Magdalena
Zbiór danych zgromadzonych w wyniku projektu badawczego pod tytułem "Nowe bioaktywne powłoki kompozytowe na bazie nanostruktur krzemionkowych dla zastosowań biologicznych i środowiskowych" finansowanego przez Narodowe Centrum Nauki w ramach konkursu SONATA-17 zawiera dane z obrazowania za pomocą elektronowej mikroskopii transmisyjnej TEM oraz skaningowej SEM badanych materiałów, spektroskopii w podczerwieni, spektroskopii Ramana, izotermicznej sorpcji azotu oraz dyfraktogramy. W zbiorze danych zamieszczono również częściowe wyniki badań własności biobójczych (MIC i MBC).; The dataset collected as a result of the research project titled "Novel bioactive composite coatings based on silica nanostructures for biological and environmental applications" funded by the National Science Centre under the SONATA-17 competition, includes data from imaging by transmission electron microscopy TEM and scanning electron microscopy SEM of the materials studied, infrared spectroscopy, Raman spectroscopy, isothermal sorption of nitrogen, and diffractograms. The dataset also includes partial results of biocidal property tests (MIC and MBC).
2024-01-01T00:00:00Z